Subject: Product Specification, Operation, Safety, and Maintenance
Subject: Product Specification, Operation, Safety, and Maintenance
Safe Shower System Components
01 SAFE SHOWER HOSPITAL
Safety
Electrical: Low voltage V12 prevents risk of electric shock to the user. Nevertheless, it is necessary to ensure no electrical current passes into the water and to obtain approval from the local electrical engineer.
Burns: The system has no heating element, therefore there is no risk of burns from operation.
Chemicals: The UV-based disinfection unit does not use any disinfectants, and no chemicals are added to the water.
Maintenance
• The UVC Led lamp lasts at least 5 years under normal use.
• The pump is designed to operate for at least 5 years under normal use.
• Water pipes and connectors are designed to last at least 8 years under normal use.
• The special silicone valves in the showerhead are designed to last at least 6 months. Upon purchase, the company commits to supplying replacement valves for one year at no additional cost.
• Full warranty on the entire product for one year, with the option for extended full service at a fixed monthly cost.
Environmental Conditions
• Ambient temperature: 4–55 °C.
• Water source: Required turbidity < 1 NTU.
• Electrical power supply: V12 source.
General Description of the Problem and Solution
Problem:
Healthcare facilities, hotels and other public buildings implement water management procedures to control Legionella risk. These may include temperature management, routine flushing, monitoring, disinfection and maintenance of shower outlets.
These procedures can involve significant operational costs, particularly in low-use rooms and facilities with many shower outlets.
Safe Shower is designed to provide an additional point-of-use treatment approach for managing residual water within the shower assembly.
Proposed Pilot Solution
Safe Shower uses patented self-sealing silicone outlet valves designed to close when water flow stops.
This closed-outlet configuration helps retain water within the shower assembly, allowing the system to perform periodic recirculation and UVC treatment during standby periods.
The pilot program is designed to evaluate the impact of this approach on Legionella levels in residual shower water, as well as its operational performance and maintenance requirements.
Assumptions for use
• Average shower use: ~10 minutes per day.
• Remaining water volume in the pipe (from the mixer to the tap outlet): ~1 liter (max).
• The NSF-approved disinfection unit can disinfect 8 liters per minute.
• Therefore, the disinfection rate is set at 8 liters/min.
• The disinfection system with circulation pump operate 2 minutes evry 2 houers 2 liters/min automatically, without user intervention - can be changed.
• The controller is programmed to schedule disinfection for 2 minutes evry 2 houers.
Target Audience
Water engineers or maintenance managers in hospitals, hotels, nursing homes, hostels and guesthouses.